The ISO15 is an isolated half-duplex differential line transceiver while the ISO35 is an
isolated full-duplex differential line driver and receiver for TIA/EIA 485/422 applications. The
ISO15M and ISO35M have extended ambient temperature ratings of 55°C to 125°C while the ISO15 and
ISO35 are specified over 40°C to 85°C.
These
devices are ideal for long transmission lines because the ground loop is broken to allow for a much
larger common-mode voltage range. The symmetrical barrier of the device is tested to provide
isolatlion of 4000 VPK per VDE and 2500 VRMS per UL
and CSA between the bus-line transceiver and the logic-level interface.
Any cabled I/O can be subjected to electrical noise transients from various sources.
These noise transients can cause damage to the transceiver and/or nearby sensitive circuitry if
they are of sufficient magnitude and duration. These isolated devices can significantly increase
protection and reduce the risk of damage to expensive control circuits.
- Meets or Exceeds TIA/EIA RS-485 Requirements
- 1/8 Unit Load – Up to 256 Nodes on a Bus
- Signaling Rates up to 1 Mbps
- Thermal Shutdown Protection
- Low Bus Capacitance – 16 pF (Typical)
- 50 kV/µs Typical Transient Immunity
- Fail-safe Receiver for Bus Open, Short, Idle
- 3.3-V Inputs are 5-V Tolerant
- Safety and Regulatory Approvals
- 4000-VPK VIOTM, 560-VPK VIORM per DIN V VDE
V 0884-10 (VDE V 0884-10):2006-12 and DIN EN 61010-1 - 2500 VRMS Isolation Rating per UL 1577
- 2500 VRMS Isolation Rating per CSA CA5A and IEC 60950-1
- APPLICATIONS
- Security Systems
- Chemical Production
- Factory Automation
- Motor and Motion Control
- HVAC and Building Automation Networks
- Networked Security Stations
All other trademarks are the property of their respective owners
| Duplex | Full |
| Data rate (max) (MBits) | 1 |
| VCC1 (min) (V) | 3.15 |
| VCC1 (max) (V) | 3.6 |
| Integrated isolated power | No |
| Operating temperature range (°C) | -40 to 85, -55 to 125 |
| VCC2 (min) (V) | 3.15 |
| VCC2 (max) (V) | 3.6 |
| Fail safe | Idle, Open, Short |
| ESD HBM (kV) | 16 |
| Rating | Catalog |
| CMTI (min) (kV/µs) | 25 |
| Isolation rating | Basic |
| Surge isolation voltage (VIOSM) (VPK) | 4000 |
| Working isolation voltage (VIOWM) (Vrms) | 400 |
| Withstand isolation voltage (VISO) (Vrms) | 2500 |
| Transient isolation voltage (VIOTM) (VPK) | 4000 |
| Creepage (min) (mm) | 8.34 |
| Clearance (min) (mm) | 8.34 |