Полупроводниковые приборы в России
+7 (812) 240-88-50
+7 (812) 240-88-50
г. Санкт-Петербург, ул. Софийская 17, лит.А, помещение 3Н оф.230

AMC3301 Texas instruments

AMC3301
Уточнить цену
AMC3301
Уточнить цену
СРАВНИТЬ
В СРАВНЕНИИ
Уточнить цену
The AMC3301 is a precision, isolated amplifier optimized for shunt-based current measurements. The fully integrated, isolated DC/DC converter allows single-supply operation from the low-side of the device, which makes the device a unique solution for space-constrained applications. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and supports a working voltage of up to 1.2 kVRMS.The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.The input of the AMC3301 is optimized for direct connection to a low-impedance shunt resistor or other, low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current measurements over the extended industrial temperature range from –40°C to +125°C.The integrated DC/DC converter fault-detection and diagnostic output pin of the AMC3301 simplify system-level design and diagnostics.
  • 3.3-V or 5-V single supply with integrated DC/DC converter
  • ±250-mV input voltage range optimized for current measurement using shunt resistors
  • Fixed gain: 8.2
  • Low DC errors:
    • Offset voltage: ±150 µV (max)
    • Offset drift: ±1 µV/°C (max)
    • Gain error: ±0.2% (max)
    • Gain error drift: ±40 ppm/°C (max)
    • Nonlinearity: ±0.04% (max)
  • High CMTI: 85 kV/µs (min)
  • System-level diagnostic features
  • Meets CISPR-11 and CISPR-25 EMI standards
  • Safety-related certifications:
    • 6000-VPK reinforced isolation per DIN VDE V 0884-11
    • 4250-VRMS isolation for 1 minute per UL1577
  • Fully specified over the extended industrial temperature range: –40°C to +125°C
Device type Current sensing
Peak-to-peak input voltage range (V) 0.25
Isolation rating Reinforced
Withstand isolation voltage (VISO) (Vrms) 4250
Working isolation voltage (VIOWM) (Vrms) 1200
Transient isolation voltage (VIOTM) (VPK) 6000
CMTI (min) (kV/µs) 85
Creepage (min) (mm) 8
Clearance (min) (mm) 8
Input offset (±) (max) (V) 0.00015
Input offset drift (±) (typ) (V/°C) 0.00000015
Rating Catalog
Operating temperature range (°C) -40 to 125
AMC3301