The TMCS1100 is a galvanically isolated Hall-effect current sensor capable of DC or AC current measurement with high accuracy, excellent linearity, and temperature stability. A low-drift, temperature-compensated signal chain provides < 1% full-scale error across the device temperature range.The input current flows through an internal 1.8-mΩ conductor that generates a magnetic field measured by an integrated Hall-effect sensor. This structure eliminates external concentrators and simplifies design. Low conductor resistance minimizes power loss and thermal dissipation. Inherent galvanic insulation provides a 600-V lifetime working voltage and 3-kVRMS basic isolation between the current path and circuitry. Integrated electrical shielding enables excellent common-mode rejection and transient immunity.The output voltage is proportional to the input current with four sensitivity options. Fixed sensitivity allows the TMCS1100 to operate from a single 3-V to 5.5-V power supply, eliminates ratiometry errors, and improves supply noise rejection. The current polarity is considered positive when flowing into the positive input pin. The VREF input pin provides a variable zero-current output voltage, enabling bidirectional or unidirectional current sensing.The TMCS1100 draws a maximum supply current of 6 mA, and all sensitivity options are specified over the operating temperature range of –40°C to +125°C.
- Total error: ±0.4% typical, ±0.9% maximum, –40°C to 85°C
- Sensitivity error: ±0.4%
- Offset error: 7 mA
- Offset drift: 0.04 mA/°C
- Linearity error: 0.05%
- Lifetime and environmental drift: <±0.5%
- 3-kVRMS isolation rating
- Robust 600-V lifetime working voltage
- Bidirectional and unidirectional current sensing
- External reference voltage
- Operating supply range: 3 V to 5.5 V
- Signal bandwidth: 80 kHz
- Multiple sensitivity options:
- TMCS1100A1: 50 mV/A
- TMCS1100A2: 100 mV/A
- TMCS1100A3: 200 mV/A
- TMCS1100A4: 400 mV/A
- Safety related certifications
- UL 1577 Component Recognition Program
- IEC/CB 62368-1
| Continuous current (max) (A) | 20 |
| Working isolation voltage (VIOWM) (Vrms) | 424 |
| Magnetic sensitivity (typ) (mV/A) | 50, 100, 200, 400 |
| Input offset current (±) (max) (mA) | 25 |
| Input offset current drift (±) (typ) (µA/°C) | 0.1 |
| Features | Externally Driven Zero Current Reference Voltage |
| Supply voltage (max) (V) | 5.5 |
| Supply voltage (min) (V) | 3 |
| Iq (max) (mA) | 6 |
| CMTI (kV/µs) | 25 |
| Small-signal bandwidth (Hz) | 80000 |
| Sensitivity error (%) | 0.2 |
| Sensitivity error drift (±) (max) (ppm/°C) | 50 |
| Rating | Catalog |
| Operating temperature range (°C) | -40 to 125 |
| Creepage (min) (mm) | 4 |
| Clearance (min) (mm) | 4 |
| Isolation rating | Basic |
| Surge isolation voltage (VIOSM) (VPK) | 6000 |