The UCC28910 and UCC28911 are high-voltage flyback switchers that provide
output voltageand current regulation without the use of an optical coupler.
Both devices incorporate a 700-Vpower FET and a controller that process
operating information from the flyback auxiliary windingand power FET to
provide a precise output voltage and current control. The integrated
high-voltage current source for startup that is switched off during device
operation, and the controller current consumption is dynamically adjusted with
load. Both enablethe very low stand-by power consumption.
Control algorithms in the UCC28910 and UCC28911, combining switching
frequency and peakprimary current modulation, allow operating efficiencies to
meet or exceed applicable standards.Discontinuous conduction mode (DCM) with
valley switching is used to reduce switching losses.Built-in protection
features help to keep secondary and primary component stress levels in check
across the operating range. The frequency jitter helps to reduce EMI filter
- Constant-Voltage (CV) and Constant-Current (CC) Output Regulation Without Optical-Coupler
- ±5% Output Voltage Regulation Accuracy
- ±5% Output Current Regulation With AC Line and Primary Inductance Tolerance Compensation
- 700-V Start-Up and Smart Power Management Enables <30-mW Standby Power
- 115-kHz Maximum Switching Frequency Design for High-Power Density
- Valley Switching and Frequency Dithering to Ease EMI Compliance
- Thermal Shut Down
- Low Line and Output Over-Voltage Protection
| Vin (min) (V) | 10 |
| Vin (max) (V) | 450 |
| Vout (min) (V) | 3.3 |
| Vout (max) (V) | 18 |
| Iout (max) (A) | 0.7 |
| Iq (typ) (mA) | 23.5 |
| Switching frequency (min) (kHz) | 0.42 |
| Switching frequency (max) (kHz) | 115 |
| Features | Adjustable switching frequency, Current limiting, Green mode, High-voltage startup, Input line monitor, Integrated Switch, IoT compatible, Leading edge blanking, Light-load efficiency, Soft start, Thermal shutdown |
| Operating temperature range (°C) | -40 to 125 |
| Rating | Catalog |
| Control mode | Current, Primary-side regulation, Voltage |
| Duty cycle (max) (%) | 99 |