The INA253 is a voltage-output, current sense amplifier with an integrated shunt resistor of 2 mΩ. The INA253 is designed to monitor bidirectional currents over a wide common-mode range from –4 V to +80 V, independent of the supply voltage. Three fixed gains are available: 100 mV/A, 200 mV/A, and 400 mV/A. The integration of the precision resistor with a zero-drift chopped amplifier provides calibration equivalent measurement accuracy, ultra-low temperature drift performance of 15 ppm/°C, and an optimized Kelvin layout for the sensing resistor.The INA253 is designed with enhanced PWM rejection circuitry to suppress large (dv/dt) signals that enable real-time continuous current measurements. The measurements are critical for in-line current measurements in a motor-drive application, and for solenoid valve control applications. This device operates from a single 2.7-V to 5.5-V power supply, drawing a maximum of 3 mA of supply current. All gain versions are specified over the extended operating temperature range (–40°C to +125°C), and are available in a 20-pin TSSOP package.
- Precision Integrated Shunt Resistor
- Shunt Resistor: 2 mΩ
- Shunt Inductance: 3 nH
- Shunt Resistor Tolerance: 0.1% (Max)
- ±15 A Continuous from –40°C to +85°C
- 0°C to 125°C Temperature Coefficient:
10 ppm/°C
- High Bandwidth: 350 kHz
- Enhanced PWM rejection
- Excellent CMRR
- > 120-dB DC CMRR
- 90-dB AC CMRR at 50 kHz
- Accuracy:
- Gain:
- Gain Error: 0.4% (Max)
- Gain Drift: 45 ppm/°C (Max)
- Offset:
- Offset Current: ±15 mA (Max)
- Offset Drift: 125 µA/°C (Max)
- Wide Common-Mode Range: –4 V to +80 V
- Available Gains: 100 mV/A, 200 mV/A,
and 400 mV/A - Quiescent Current: 2.4 mA (Max)
| Common-mode voltage (max) (V) | 80 |
| Common-mode voltage (min) (V) | -4 |
| Gain error (%) | 0.4 |
| Gain error drift (±) (max) (ppm/°C) | 45 |
| CMRR (min) (dB) | 120 |
| Bandwidth (kHz) | 350 |
| Supply voltage (max) (V) | 5.5 |
| Supply voltage (min) (V) | 2.7 |
| Iq (max) (mA) | 2.6 |
| Features | Bi-directional, Enhanced PWM Rejection, Integrated Shunt, Low-side Capable |
| Rating | Catalog |
| Operating temperature range (°C) | -40 to 125 |